Posts

Showing posts from February, 2020

EC Level Pin Gasket and Teflon Tape

Image
EC Level Pin News Level Pin Gasket Technicians, please inspect gasket on level pin when cleaning and replace if needed. We have had success with the problem of boiler chatter with cleaning the pin and possible added filter. But, if chatter persists, it is likely a new gasket will help. The gasket part number is 1561098 . Teflon Tape in Normal Open Valve  As seen below in the latest service info, if your boiler has an unusually high temp and possible warm water leak into drip tray, there may be Teflon tape stuck in the Normal Open Valve. Please remove and clean out valve as instructed and please follow these taping instructions. PLEASE NOTE: This condition could also be on a brand new machine upon install!